Skip to main content

Specifications

Physical​

NUC PROHR-01-2
Closed size24 × 22 × 10.5 in, lids on, wheels and handle retractedSame
Weight, no box92.7 lb (42 kg)87 lb (39.5 kg)
Shipping box28 × 28 × 14 in, about 110 lb (50 kg)Same
EDC legs10.6 in, fixed height, 26.5 × 26.5 in footprint. Case top about 1.7 ft off the groundSame
MastMain pole 40-121 cm, extension 40-63 cm, both 184 cm (6 ft). Up to 8.4 ft from the ground with legs, T-bar and beacon. 3 lb (1.36 kg) top load, centeredSame
Work surface / bench8 lb (3.6 kg) / 220 lb (100 kg), sitting onlySame
AirflowFront to rear, no side ventsSame

Deployed dimensions

Compute and network​

NUC PROHR-01-2
Nodes3 × NUC PRO (NUC 15 Pro), 2 × 2.5GbE each2 × HR-01 edge servers, 2 × 10G SFP+ and 2 × 2.5GbE each, 10G DAC between nodes
Switch, standardEnGenius ECS2510FP: 8 × 2.5GbE PoE+, 2 × 10G SFP+, 240 W PoESame
Switch, upgradedEnGenius ECS5512FP: 8 × 10GbE PoE++, 4 × 10G SFP+, 420 W PoESame
MonitoringHiveSight on the HiveSight SBC, PoE poweredSame
HCI, factory pre-installStorMagic SvHCI or NodeWeaverSame

See the datasheet for node CPU, memory and storage options.

Power​

PDUEnGenius ECP106 (100-120 V, 12 A) or ECP106-INT (200-240 V, 10 A), 50/60 Hz, 6 outlets
Inlet and cordC13 inlet; 6 ft (1.83 m) cord, NEMA 5-15P (NA) or Schuko (INT, others on request)
BatteriesHiveRadar Off-Grid Delta 3 Pro, Delta 3 Plus; any pure sine wave UPS or generator

Typical power draw is around 200-250 W, depending on the edition, the options and the workload.

Environment​

Operating5 to 35 °C (41 to 95 °F)
Recommended15 to 27 °C (59 to 81 °F)
Storage-20 to 60 °C (-4 to 140 °F)
Humidity10 to 85% operating, 5 to 95% storage, non-condensing
UseSheltered only: tent, trailer, office or covered space. Not weatherproof
FansStart at 25 °C in the top drawer; Eco, Balanced (default) and Turbo profiles