Specifications
Physical
| NUC PRO | HR-01-2 | |
|---|---|---|
| Closed size | 24 × 22 × 10.5 in, lids on, wheels and handle retracted | Same |
| Weight, no box | 92.7 lb (42 kg) | 87 lb (39.5 kg) |
| Shipping box | 28 × 28 × 14 in, about 110 lb (50 kg) | Same |
| EDC legs | 10.6 in, fixed height, 26.5 × 26.5 in footprint. Case top about 1.7 ft off the ground | Same |
| Mast | Main pole 40-121 cm, extension 40-63 cm, both 184 cm (6 ft). Up to 8.4 ft from the ground with legs, T-bar and beacon. 3 lb (1.36 kg) top load, centered | Same |
| Work surface / bench | 8 lb (3.6 kg) / 220 lb (100 kg), sitting only | Same |
| Airflow | Front to rear, no side vents | Same |

Compute and network
| NUC PRO | HR-01-2 | |
|---|---|---|
| Nodes | 3 × NUC PRO (NUC 15 Pro), 2 × 2.5GbE each | 2 × HR-01 edge servers, 2 × 10G SFP+ and 2 × 2.5GbE each, 10G DAC between nodes |
| Switch, standard | EnGenius ECS2510FP: 8 × 2.5GbE PoE+, 2 × 10G SFP+, 240 W PoE | Same |
| Switch, upgraded | EnGenius ECS5512FP: 8 × 10GbE PoE++, 4 × 10G SFP+, 420 W PoE | Same |
| Monitoring | HiveSight on the HiveSight SBC, PoE powered | Same |
| HCI, factory pre-install | StorMagic SvHCI or NodeWeaver | Same |
See the datasheet for node CPU, memory and storage options.
Power
| PDU | EnGenius ECP106 (100-120 V, 12 A) or ECP106-INT (200-240 V, 10 A), 50/60 Hz, 6 outlets |
| Inlet and cord | C13 inlet; 6 ft (1.83 m) cord, NEMA 5-15P (NA) or Schuko (INT, others on request) |
| Batteries | HiveRadar Off-Grid Delta 3 Pro, Delta 3 Plus; any pure sine wave UPS or generator |
Typical power draw is around 200-250 W, depending on the edition, the options and the workload.
Environment
| Operating | 5 to 35 °C (41 to 95 °F) |
| Recommended | 15 to 27 °C (59 to 81 °F) |
| Storage | -20 to 60 °C (-4 to 140 °F) |
| Humidity | 10 to 85% operating, 5 to 95% storage, non-condensing |
| Use | Sheltered only: tent, trailer, office or covered space. Not weatherproof |
| Fans | Start at 25 °C in the top drawer; Eco, Balanced (default) and Turbo profiles |