Skip to main content

HCI Software

The compute nodes run hyperconverged infrastructure (HCI) software: virtual machines, storage shared across the nodes, and failover if a node goes down.

Platforms​

PlatformStatusGuide
StorMagic SvHCIHiveRadar is authorized to pre-install it at the factoryStorMagic SvHCI
NodeWeaverHiveRadar is authorized to pre-install it at the factoryNodeWeaver, NodeWeaver docs
Proxmox VE, Scale Computing HC3, HarvesterValidated to run on P-EDC hardware, but not supported by HiveRadarYour partner or the vendor

What HiveRadar sets up when it pre-installs​

  • The HCI installed, clustered and licensed on all nodes
  • Switch: the ports carrying node data set to a tagged VLAN (802.1Q) trunk. The gateway port is not trunked. Everything else stays at the factory setting
  • StorMagic: the witness enabled on the HiveSight SBC
  • Access & Configuration Sheet: an extra page with the cluster address, login, node hostnames, IPs and serials, and the licence

If you install an HCI yourself, set up the switch trunking for it. Without a pre-installed HCI, the switch is one flat network with no VLANs.

Node networking​

Each of the 3 nodes has two 2.5GbE ports, both connected to the switch (ports 1-6).

Full port maps: Ports and Addresses.

Log in​

Your HCI address and login are on the HCI page of your Access & Configuration Sheet. If you can't find a node's address, check the DHCP lease list of your gateway or site network, or connect a monitor and keyboard to the node and read it from the console.

Change the initial password at first login.

Monitor it in HiveSight​

HiveSight can be set up to monitor the cluster. It is not automatic: add the connection in the setup wizard and check it shows as connected. See HiveSight Setup.

Support​

HCI software issues go to your partner, who involves the vendor when needed. Hardware issues go to your partner or HiveRadar. See Support and Warranty.