HiveRadar P-EDC Documentation
The HiveRadar Portable Edge Data Center (P-EDC) is a 4U ruggedized case with compute nodes, a managed PoE switch, a smart PDU and the HiveSight monitoring board, all wired and tested at the factory. These docs take you from the box to running workloads, then cover day-to-day operation.
Pick your edition
Your edition is on the label on the rear panel, below the PDU, and on your welcome letter. Pages with edition-specific steps show tabs; pick your edition once and every page follows it.
How these docs are organized
| Section | Use it when |
|---|---|
| Deploy | You are setting up a P-EDC. Follow the steps in order, from site check to HiveSight |
| Operate | The unit is running and you need to manage it, power it from batteries, or pack it up |
| Reference | You need a port, address, spec or fix |
| Quick Start Videos | You prefer to watch the physical steps first |
What's in a P-EDC
| Part | NUC PRO | HR-01-2 |
|---|---|---|
| Compute | 3 × NUC PRO nodes | 2 × HR-01 edge servers, with a direct 10G link between them |
| Switch | EnGenius ECS2510FP (8 × 2.5GbE + 2 × 10G SFP+), or the upgraded ECS5512FP (8 × 10GbE + 4 × 10G SFP+) | Same |
| PDU | EnGenius ECP106 (100-120 V) or ECP106-INT (200-240 V), 6 outlets | Same |
| Monitoring | HiveSight on the HiveSight SBC, powered by PoE from the switch | Same |
| HCI software | StorMagic SvHCI or NodeWeaver, pre-installed by HiveRadar when ordered | Same |
| Storage drawers | Top drawer for the pole, beacon and gateway; lower drawer holds a Starlink Mini | Top drawer as NUC PRO; lower drawer for accessories (Starlink Mini goes in the optional backpack) |
Getting help
Contact your partner or distributor first. They work with HiveRadar, and HiveRadar involves the relevant vendor when needed. See Support and Warranty.